Solutions
Reinigen for a panel. MPTS for the whole facility.
Two ways to correct power factor and harmonics, each sized from measurements of your own system.
Which One Fits
Start from the size of the problem.
| Attribute | Reinigen | MPTS |
|---|---|---|
| Scope | One panel or switchboard | The whole facility, at the main service |
| Service | 480 V three-phase, 4-wire | 480 V three-phase |
| Correction | 60–120 kVAR per unit; units connect in parallel | H240: 200 kVAR, services to 1,000 A. H490: 400 kVAR, services to 2,000 A |
| Typical load | Smaller panels and lower-load areas | Roughly 150 kW or more |
| Start with | A survey and temporary metering of the panel | Monitoring meter, $5,000, credited to the system |
| Made by | Accentz, Inc., Aurora, Colorado | Trans Power Company, its developer and patent holder |
Around the Equipment
Measurement comes with every project.
01
Power-quality survey
A walk-through of your distribution, loads and operating conditions, and the concerns your team already has.
02
Temporary monitoring
Professional metering of voltage, current, kW, kVA, kVAR, power factor, harmonics, imbalance and transients.
03
Engineering report
Root causes, their technical and financial impact, and corrective actions in priority order.
04
Performance verification
Measurement after installation, and yearly if you want it, so the result stays documented.
Compare Technologies
How MPTS compares with other power-quality equipment.
| Category | What it does |
|---|---|
| Capacitor banks | Fix one issue: power factor |
| Harmonic filters | Fix one issue: harmonics |
| Surge protectors (SPD) | Protect from one issue: transients |
| Energy management systems | See everything, fix nothing |
| MPTS | Sees, fixes and optimizes, system-wide |
By function
Swipe the table sideways to see every column.
| Solution | Power factor | Harmonics | Transients and surges | Efficiency and losses | Dynamic control and remote access | Scope |
|---|---|---|---|---|---|---|
| Capacitor banks / APFC panels | Yes, lagging power factor only | No | No | Limited; may cause resonance | No; limited to its function | Narrow: power-factor correction only |
| Harmonic filters | No | Yes, specific frequencies | No | Limited; focused on harmonics | No; limited to its function | Narrow: harmonics only |
| Surge protectors (SPD) | No | No | Yes, clamps surges and spikes | No | No; limited to its function | Narrow: transient events |
| Energy management systems | No | No | No | No | Yes, real-time and historical data | Monitoring only; corrects nothing |
| MPTS | Yes, dynamic and optimized | Yes, broad suppression | Yes, transient and surge suppression | Yes, cuts I²R losses, heat and reactive power | Yes, real-time adaptive control, with historical data and M&V reports | Comprehensive: all-in-one system |
Source: Trans Power Company’s comparison of power-quality solutions, 2026. The takeaway is its own: individual devices each target one issue; MPTS addresses them together.